Phone

(+65) 6284 3818

Email

sales@premier-sols.com

Enquriy
Single channel potentiostat model CS120

Single channel potentiostat model CS120

0.0/5 rating (0 votes)

Description

Specifications

Support 2-, 3- or 4-electrode system
Potential control range: ±10V
Current control range: ±2A
Potential control accuracy: 0.1%×full range±1Mv
Current control accuracy: 0.1%×full range
Potential resolution: 10μV (>100Hz),3μV(<10Hz)
Current sensitivity:1pA
Rise time: <1μS (<10mA), <10μS (<2A)
Reference electrode input impedance:1012Ω||20pF
Current range: 2nA~2A, 10 ranges
Compliance voltage: ±21V
Maximum current output: 2A
CV and LSV scan rate: 0.001mV~10,000V/s
CA and CC pulse width: 0.0001~65,000s
Current increment during scan: 1mA@1A/ms
Potential increment during scan: 0.076mV@1V/ms
AD data acquisition:16bit@1 MHz,20bit@1 kHz
DA Resolution:16bit, setup time:1μs
Minimum potential increment in CV: 0.075mV
Low-pass filters: Covering 8-decade
Potential and current range: Automatic
Interface: USB
Operating System: Windows 2000/NT/XP/ win7/win8/win10
Weight/ Instrument size: 6kg, 36 x 30 x16cm

 

CS120 Potentiostat contains a fast digital function generator, high-speed data acquisition circuitry, a potentiostat. 
Model CS120 is the simplest model. Only potentiostat is integrated. No galvanostat. It’s suitable for those who have low budget and just want to do the most basic experiments such as CV, LSV, OCP.

                                                                   SOFTWARE FEATURES
CS studio software provides users a versatile smoothing/differential/ integration kit, which can complete the calculation of peak height, peak area and peak potential of CV curves.

CS studio also provides powerful non-linear fitting on Butler-Volmer equation of polarization curve. It can calculate Tafel slope, corrosion current density, limitation current, polarization resistance, corrosion rate. It can also calculate the power spectrum density, noise resistance and noise spectrum resistance based on the electrochemical noise measurements.
CS Studio software can achieve real time saving of the measuring data. The data can be automatically saved even in case of sudden power off.
CS studio kit has a built-in versatile timing policy for combined measurements, which can facilitate the automation of experiments and save time.  
 
TECHNICAL ADVANTAGES
1. Polarization curve
It can complete linear polarization curve and Tafel plot measurements. The user can set the anodic reversal current (passivation film breakdown current) of the cyclic polarization curve to determine material’s pitting potential and protection potential and evaluate the its susceptibility to intergranular corrosion. The software employs non-linear fitting to analyze polarization curve, and can make fast evaluation of material’s anti-corrosion ability and inhibitors.
  

Polarization curve of Ti-based amorphous alloy & stainless steel in 3%NaCl solution
2. Voltammetry 
It can do the following electroanalysis methods: Linear Sweep Voltammetry(LSV), Cyclic Voltammetry(CV). It integrates calculation of peak area, peak current and standard curve analysis.
    LSV curve: mesoporous carbon material in 0.1M KOH    
 
CV curves of PPy supercapacitor in 0.5 mol/L H2SO4
 
 
 
 
Standard supply list for potentiostat Model CS120
Instrument host CS120*1
CS studio software(Testing & data analysis)*1
Power cable*1
USB cable *1
Electrode cable *2
Dummy cell*1
**If you need electrodes and cells, please kindly contact us for purchase.
 
Service 1. Warranty period: 5 years
2. Provide installation guidance and manual, software installation video.
3. Lifetime free software upgrading and technical service
4. Provide repair service for free
 
 
 

LSV curve: mesoporous carbon material in 0.1M KOH 

Share this product

Please type your full name.
Invalid email address.
Invalid Input
Invalid Input

Register for new product information:    

Please publish modules in offcanvas position.