Working Voltage | - AC 220V 50/60 Hz Single Phase
|
Max Power Consumption | |
Assembled Glovebox | - Material: Stainless Steel 304
- Dimensions:7800 mm (L) x 1050 mm (W) x 2000 mm (H)
- 12 mm thick double layer laminated safety glass with corrosion protection film for operating in a safe and easy manner
- Five main chambers and three purification systems
- Can be divided into three separated units: [Chamber 1,2]: [Chamber 3,4]: [Chamber 5]
- Ample space for the cell fabrication line
|
Main Chamber | - Dimensions for single chamber: 1200 (L) × 800 (W) × 930 mm (H)
- Water concentration: < 1 ppm (20°C, 1 atm)
- Oxygen concentration: < 1 ppm (20°C, 1 atm)
|
Leak Rate | - <0.05 Vol% / hr (Depending on oxygen concentration inside the glove box)
|
Airlock Chamber | - Two Antechambers and two small chambers on both sides of the glove box
- Antechamber Dimension: 385 mm (Dia.) x 588 mm (L)
- Small Chamber Dimension: 150 mm (Dia.) x 300 mm (L)
- Maximum vacuum level: 100 Pa
|
Working Gas | - Operating gas: Inert gas such as N2, Ar, He
- Regeneration gas: Mixture of H2(5%) and Operating gas
- For purification system with only water adsorbing function, Regenerating gas would be the same as Operating gas
|
Filter System | - Two Purification Cylinders included due to the large glove box
- Organic Solvent Filter System filled with replaceable activated carbon
- Built-in HEPA filter can eliminate particle size > 0.3μm
|
Control System | - Siemens PLC control system with 6" touchscreen display
- Water concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm
- Oxygen concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm
- Pressure: -2500 to 2500 Pa with an accuracy of 1Pa
- Purification limitation
- Water concentration: <1 ppm (20°C, 1 atm)
- Oxygen concentration: <1 ppm (20°C, 1 atm)
- Regeneration Temperature Controlleris built-in for automatically regenerating the filters
- Automatically purging function is built-in for quick reducing O2 < 200ppm & H2O < 50 ppm before recycling.
- The automatic pressure control system is built in to keep the pressure at a constant level.
|
Pump | - 240 L/m Heavy Duty Double Stage Rotary Vane Pump for the gas exhaust
- Vacuum rate: 7.8 CFM
- Lowest pressure: 0.4 Pa
|
Blower | |
Purification Pipeline | - 304 Stainless Steel, KF40 Port
|
Gloves | - A pair of NORTH Butyl glove is included to provide better protection against toxic materials for one chamber
- Four pairs in total
|
Lighting | |
Slidable Shelf | - Five slidable shelves are built on top of inside glove chamber with dimensions of 300mm x 250mm
- 300 mm away from the roof
|
Separating Door (optional) | - The separating door is designed to separate the chamber when the accident happens, and let other chambers keep running.
- The shutter doors shown are in the chamber 2nd and 4th.
|
Optional | - The universal terminal panel is a convenient part with various feedthrough built-in for VGB series glove boxes to transfer gas/vacuum pipelines, circuit cables, etc. ( Pic. 1-2)
- Dimensions: 420x280mm
- Adapter: 10 Φ6 ports, 4 Φ8 ports, 4 Φ12 ports
- Heatable Antechamber: 200C max., DN385×588mm (L), extra cost $7699
- The extra purification system is available to avoid accidents happen.
- Carbon filtering and sloven vaper filtering systems are available upon request. (Pic. 6)
Pic. 1 Pic. 2 Pic. 3 Pic. 4 Pic. 5 Pic. 6 |
Product Dimensions | - 7800 mm(L) x 1050 mm(W) x 2000 mm(H) (310" x 41" x 78")
|
Shipping Dimension & Weight | |
Operation Instructions | |
Warranty | - One-year limited warranty with lifetime support
- Rusting and damage due to the improper storage condition or maintenance would not be covered by warranty
- Gloves are consumable parts and are not covered by warranty
|
Application Notes & Warnings | - The use of corrosive gasses is prohibited as they will damage the water and oxygen sensors.
- Regularly perform regeneration to maintain optimum purification efficiency.
- The O2 removing rate is largely dependent on the type of purging gas used. For a faster chamber purging process, Nitrogen is preferred over Argon due to its lighter mass.
- Corrosive liquid (such as LiPF6 electrolyte) must be remain sealed in a container inside the glove box. Otherwise, liquid-vapor may condense and corrode the steel chamber and purification pipeline
|