For any application involving processing gas in the furnace, to ensure the safe use of furnace flange, please always install the two stage gas regulator to the cylinder. Read the furnace instruction to understand the pressure rating of each part in the system. Determine and limit the input gas pressure before the operation to avoid overpressure which could cause damages to pressure gauge, needle valve or other fittings. Failure to install gas regulator could cause severe personal injury.
Installation
1. Connect the gas regulator to gas Cylinder. Install a 1/4" tube fitting to the outlet of the gas regulator. | 2. Install another 1/4 tube fittings in the flange. Use a 1/4 stainless steel or PTFE tube (low pressure) to connect the gas regulator and flange. NOTE: Make sure the thread type of the 1/4 tube fittings before installation. For most gas regulator in U.S., the 1/4 tube fitting is required to have 1/4 MNPT thread type. For MTI flange system, the 1/4 tube fitting is required to have 1/4 MBSPP thread type. | 3. Finish Installation. |
Specifications of CGA-8700 gas regulator
Features: |
|
Maximum Rated Inlet Pressure | 2,500 psi (It is hard to Regulate below 500 psi, if you need low pressure , please order CGA-580-LD) |
Inlet | CGA 580 |
Application Note | For high-pressure Furnace only, |